Pathology Handbook

 New search
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # ALL

Chromium Plasma (Sendaway Test)

Alternative Names:Plasma Chromium
Laboratory:Clinical Biochemistry
Test Code:CHP
Medicare rebatable:Yes
Specimen Types:Plasma
Container Types:
Metal-Free EDTAMetal-Free EDTA
Adults Volume or Mass:6 mL
Minimum/Paediatric Volume or Mass:2 mL
Collection & Request Instructions:Collect at ambient temperature

For monitoring occupational exposure not nutritional deficiency.

To limit the possibility of contamination, the first collected tube should not be used for Chromium. If no other tubes need to be collected please collect 2 tubes and discard first collected. High concentrations of Gadolinium and Iodine are known to interfere with most metals tests. If either Gadolinium- or Iodine- containing contrast media has been administered, a specimen should not be collected for at least 96 hours.

This collection can be shared with Cobalt.

Transport Instructions:Room Temperature

USEFUL LINKS

 

Frozen Section Booking Form

Printable Pathology Request Form

Order of Draw - Blood Samples